Furuno – Furuno GP-3500 User Manual
Page 191
FURUNO
GP-3500
SP - 2
E4421S01C
Range and bearing to cursor intersection,
Water temperature and water depth (sensor data required)
4 INTERFACE
4.1
Number of ports
Input: 3 ports, Output: 2 ports
4.2
Input data
IEC 61162-1, NMEA0183 Ver1.5/2.0
Sentences
BWC, BWR, DPT, DBT, DBK, DBS, GGA, GLC, GLL, GNS, GTD,
HDT, HDG, HDM, MTW, RMA, RMB, RMC, RTE, TLL, TTM, VHW,
VTG,
ZDA
4.3
Output data
IEC 61162-1, NMEA0183 Ver1.5/2.0
Sentences
AAM, APB, BOD, BWC or BWR, DPT or DBT, GGA, GLL, GNS,
GTD, HDG, HDT, MTW, MWV, RMA, RMB, RMC, RTE, TTM,
VHW, VTG, WPL, XTE, ZDA
4.4
I/O data
RS-232C for PC
5 POWER
SOURCE
5.1
Display unit
12-24 VDC: 1.5-0.8 A
6 ENVIRONMENTAL
CONDITIONS
6.1
Ambient temperature
Antenna unit: -25
to + 70
Display unit: -15
to + 55
6.2
Relative humidity
95% (40
)
6.3
Waterproof
Antenna unit: IPX6
(IEC60529)
Display unit: IPX2 (external monitor attached: IPX0)
6.4 Vibration
IEC
60945
7 COATING
COLOR
7.1
Display unit
Chassis: Munsell 2.5GY5/1.5, Panel: N3.0
7.2
Antenna unit
N9.5 (white)
8
COMPASS SAFE DISTANCE
8.1 Display
unit
Standard:
0.6 m
Steering: 0.4 m