3-6
P/N 480-0062-00-10
Chapter 3: Installation/Basic Troubleshooting
Double-ended 50-pin Cable
The connectors on the double-ended cable are provided with a grounding shield and strain relief
screws, as shown in the following figure.
Figure 2-4 Torque down screws to make ground
1. You should ensure that the screws are torqued down at the Tenor AX and at the opposite end of the cable,
as follows.
•
See item 7 in the previous section for the torque specs for the Tenor AX side.
•
At the opposite end, if the screw is being secured into plastic, then the torque is
3.0 - 3.5 in. lbs. (0.34 - 0.39 Nm).
•
If the screw is being secured into metal, then the torque is 4.5 - 5.0 in. lbs.
(0.51 - 0.57 Nm).
2. Ensure that the grounding shield at the termination point is connected to an appropriate earth ground.
Cable
Grounding
Screw