FGR2-PE Wirelss Data Transceiver
LUM0024AB Rev A
Trap Manager IP
Web Parameter:
Trap Manager 1 IP and Trap Manager 2 IP in the SNMP Trap Configuration
section of the SNMP page.
Network Type:
Both
Default Setting:
0.0.0.0
Options:
Any valid IP address.
Description:
The IP addresses of the authorized SNMP Trap Managers. DNS names are
not accepted.
Trap Version
Web Parameter:
Trap Version in the SNMP Trap Configuration section of the Security page.
Network Type:
Both
Default Setting:
Disabled
Options:
Disabled, v1, v2
Description:
The trap version supported by the SNMP Agent.
Write Community
Web Parameter:
Write Community in the SNMP Agent Configuration section of the SNMP
page.
Network Type:
Both
Default Setting:
Blank
Options:
Any free form text up to 25 characters.
Description:
SNMP community name that has write access.
SNMP Trap Limit Parameter Reference
This section contains the following information as it applies to the high and low trap limits that you can set for
the transceivers described in this document. In Tool Suite, the fields for the trap limits display when the Trap
Version parameter is set to anything other than Disabled. In the configuration Web pages, use the check
boxes and drop-down lists in the SNMP Trap Limits section of the SNMP page to set the trap limits.
parameter name (as you see it in Tool Suite)
Web Parameter:
The name of the field as it appears in the configuration Web pages.
Network Type:
Point-to-Point, Point-to-MultiPoint, or Both
Default Setting:
The factory default setting for the parameter.
Options:
The options to which the parameter can be set.
Description:
A description of what the parameter is and how it applies to the transceiver in
80