Vswr alarm enable, Voltage alarm above, Voltage alarm below – Baseline Systems FreeWave Ethernet Radio User Manual

Page 100: Voltage alarm enable

background image

FGR2-PE Wirelss Data Transceiver

LUM0024AB Rev A

VSWR Alarm Enable

Web Parameter:

Reflected Power Enable check box in the SNMP Trap Limits section of the
SNMP page.

Network Type:

Both

Default Setting:

Disabled

Options:

Disabled, Enabled

Description:

Enables a trap for the reflected power of the transceiver. The trap condition is
present based on the settings in the VSWR Alarm Above parameter.

Voltage Alarm Above

Web Parameter:

Voltage Alarm Above in the SNMP Trap Limits section of the SNMP page.

Network Type:

Both

Default Setting:

30

Options:

Any whole number between 6 and 30.

Description:

If the Voltage Alarm Enable option is set to Enabled, a trap condition occurs
if the voltage goes above the value in this parameter.

Voltage Alarm Below

Web Parameter:

Voltage Alarm Below in the SNMP Trap Limits section of the SNMP page.

Network Type:

Both

Default Setting:

6

Options:

Any whole number between 6 and 30 VDC.

Description:

If the Voltage Alarm Enable option is set to Enabled, a trap condition occurs
if the voltage goes below the value in this parameter.

Voltage Alarm Enable

Web Parameter:

Voltage Enable check box in the SNMP Trap Limits section of the SNMP
page.

Network Type:

Both

Default Setting:

Disabled

Options:

Disabled, Enabled

Description:

Enables a trap for the supply voltage of the transceiver. The trap condition is
present based on the settings in the Voltage Alarm Above and Voltage
Alarm Below
parameters.

84