Attention:

In

the

initial

installation

of

the

DS4100,

you

can

add

only

new

expansion

units

to

the

DS4100

storage

server.

This

means

that

there

must

be

no

existing

configuration

information

on

the

expansion

unit

that

you

want

to

install.

If

the

expansion

unit

that

you

want

to

install

currently

contains

logical

drives

or

configured

hot

spares,

and

you

want

them

to

be

part

of

the

DS4100

storage

server,

refer

to

the

IBM

TotalStorage

DS4000

Hard

Drive

and

Storage

Expansion

Enclosure

Installation

and

Migration

Guide.

Improper

drive

migration

might

cause

loss

of

configuration

and

other

storage

server

problems.

Contact

your

IBM

support

representative

for

additional

information.

To

connect

a

single

additional

expansion

unit

to

the

storage

server,

perform

the

following

steps:

Note:

The

following

procedures

are

for

″cold-case″

procedures

(the

DS4100

is

powered

down

when

expansion

units

are

connected,

as

in

the

case

of

a

new

installation).

For

″hot-case″

procedures

(the

DS4100

is

powered

on

when

expansion

units

are

connected),

see

“Adding

a

DS4000

EXP100

to

an

existing

DS4100

configuration

(base

storage

server

only)”

on

page

109.

You

can

also

refer

to

the

IBM

TotalStorage

DS4000

Hard

Drive

and

Storage

Expansion

Enclosure

Installation

and

Migration

Guide.

1.

Follow

the

instructions

in

your

expansion

unit

installation

manual

to

set

up

and

mount

the

new

expansion

unit.

2.

Use

the

following

procedure

and

Figure

53

on

page

59

to

connect

a

single

expansion

unit

to

the

storage

server:

a.

Ensure

that

the

enclosure

ID

switch

on

the

new

expansion

unit

is

set

to

a

value

different

than

the

value

set

for

the

DS4100

and

any

other

expansion

units

in

the

loop.

Also

ensure

that

the

link

speeds

of

the

expansion

units

are

set

to

2

Gbps.

See

“Setting

the

interface

options”

on

page

32.

Note:

When

connecting

the

DS4100

to

DS4000

EXP100

storage

expansion

units,

do

not

use

the

tens

digit

(x10)

setting.

Use

only

the

ones

digit

(x1)

setting

to

set

unique

server

IDs

or

enclosure

IDs.

For

more

information,

see

“Server

ID

(enclosure

ID)

settings”

on

page

33.

b.

Use

a

fiber-optic

cable

to

connect

to

the

FC-Expansion

Units

port

on

the

left

RAID

controller

in

the

storage

server

to

the

In

port

on

the

left

ESM

board

of

the

expansion

unit.

c.

Use

a

second

fiber-optic

cable

to

connect

the

FC-Expansion

Units

port

on

the

right

RAID

controller

in

the

storage

server

to

the

Out

port

on

the

right

ESM

board

of

the

expansion

unit.

58

IBM

TotalStorage

DS4100

Storage

Server:

Installation,

User’s,

and

Maintenance

Guide