beautypg.com

Figures used in this document, Ds4000 installation process overview, Figures – IBM Partner Pavilion DS4100 User Manual

Page 21: Used, This, Document, Ds4000, Installation, Process, Overview

background image

v

Danger:

These

statements

indicate

situations

that

can

be

potentially

lethal

or

extremely

hazardous

to

you.

A

danger

statement

is

placed

just

before

the

description

of

a

potentially

lethal

or

extremely

hazardous

procedure

step

or

situation.

Figures

used

in

this

document

The

figures

used

in

this

document

are

for

illustrative

purposes

only.

In

some

cases,

the

actual

device

might

look

different

from

the

figure.

Note:

This

applies

particularly

in

cases

where

the

DS4100

single-controller

storage

server

differs

from

the

DS4100

base

storage

server.

DS4000

installation

process

overview

The

following

flow

chart

gives

an

overview

of

the

DS4000

hardware

and

the

DS4000

Storage

Manager

software

installation

process.

Lined

arrows

in

the

flow

chart

indicate

consecutive

steps

in

the

hardware

and

software

installation

process.

Labeled

arrows

indicate

which

current

documents

provide

detailed

information

about

those

steps.

Install Process

Documentation

Plan installation

Connect Power and

Start Server

DS4000 Storage Server

Installation Guide

Complete SM SW

Installation

Configure Storage

Hardware

Online Help

Configure Storage

Subsystems on Host

Verify Server

operation w/ LEDs

Prepare for

Installation of

SM Software

Install and Verify

SM SW on Host and

Workstation

* FC Planning and

Integration: User's Guide

and Svc Info

DS4000 Storage Manager

Concepts Guide

DS4000 Storage Exp Units

Install and User's Guides

DS4000 Fibre Channel

Storage Server

Installation Guides

Fibre Channel Cabling

Instructions

DS4000 and HBA Install

and User's Guides

DS4000 Storage Svr

Installation Guide

DS4000 RAID Controller

Enclosure Unit Install

and User's Guide

Copy Services

User's Guide

DS4000 Storage Manager

DS4000 Storage

Manager Installation

and Support

OS Guides

DS4000 Hardware

Maintenance Manual

DS4000 Problem

Determination Guide

Out-of-Band

In-Band

Make FC Connections

SET Link Speed

(1GB or 2GB)

Install Storage

Server/RAID Controller

Enclosure(s) in Rack

Install Network

Hardware; Prep are

Network Connection

Install Storage

Expansion Unit(s)

Determine

Management

Method

* For pSeries Server and 6227 or 6228 HBA use only

sj001046

Figure

1.

Installation

process

flow

by

current

publications

About

this

document

xix