beautypg.com

Direct (out-of-band) management method, Direct, Out-of-band) – IBM Partner Pavilion DS4100 User Manual

Page 67: Management, Method, Host-agent, In-band), Managed, Storage, Subsystems

background image

Ethernet

Host-agent

software

Client software

Controller

Controller

Controller

Controller

Fibre Channel
I/O path

Management station

(one or more)

Note: The client software is

installed on one or more

management systems,

or on the host computer.

f10ug004

Direct

(out-of-band)

management

method

This

method

uses

Ethernet

connections

from

a

management

station

to

each

controller.

You

must

install

at

least

one

management

station.

The

management

station

can

be

the

host

or

a

workstation

on

the

Ethernet

network.

A

management

station

will

have

the

client

software

installed.

Attach

Ethernet

cables

to

each

management

station

(one

pair

per

storage

server).

You

will

connect

the

cables

to

each

storage

server

controller

later

when

you

install

the

storage

server.

Figure

24

on

page

36

shows

the

direct

(out-of-band)

management

method.

Note:

Do

not

connect

the

DS4100

storage

server

Ethernet

ports

to

a

public

network

or

public

subnet.

It

is

strongly

recommended

that

you

create

a

private

network

between

the

DS4100

storage

server

and

the

management

station.

Figure

23.

Host-agent

(in-band)

managed

storage

subsystems

Chapter

2.

Installing

the

storage

server

35