1 rmon alarm : create new alarm, Figure 79 rmon alarm : create new alarm, Table 60 rmon alarm : create new alarm – IronPort Systems ES-1528 User Manual
Page 127

Chapter 19 RMON-Lite
ES-1528 User’s Guide
127
19.5.1 RMON Alarm : Create New Alarm
Use the RMON Alarm : Create New Alarm screen to configure RMON alarms. Click
Create new Alarm or click on an existing alarm index entry in the RMON Alarm :
Overview screen to view the screen as shown.
Figure 79 RMON Alarm : Create New Alarm
The following table describes the labels in this screen.
RisingThreshold This field displays the rising threshold value set up for this alarm.
FallingThreshol
d
This field displays the falling threshold value set up for this alarm.
Rising Event
Index
This field indicates the index number of the event entry which corresponds to the
time when the alarm threshold was crossed.
Falling Event
Index
This field indicates the index number of the event entry which corresponds to the
time when the alarm threshold was crossed.
Owner
This field displays the name of the creator of this entry.
Delete
Click this to remove the selected alarm entry.
Table 59 RMON Alarm: Overview (continued)
LABEL
DESCRIPTION
Table 60 RMON Alarm : Create New Alarm
LABEL
DESCRIPTION
RMON MIB
Table:
Use this drop down list box to select the MIB table you want to view. Click Apply to
refresh the screen to the selected MIB table view.
Index
This field displays the index number of this alarm entry.
Interface
Select the port which is monitored for this alarm.
Counter
Select the data which is used to test if this alarm is triggered, the choices are Drop
Events, Octets, Packets and so on.