Intelligent Motion Systems Modular LYNX System User Manual
Page 51

1 - 51
Modular L
YNX System
Modular LYNX System 12.05.2003
S e c t i o n 1 0
T h e D i f f e r e n t i a l D i g i t a l I / O M o d u l e
S e c t i o n O v e r v i e w
A LYNX system may contain an optional Differential I/O Module (IMS Part# LX-DD100-000) which provides
six (6) high speed differential I/Os. These I/Os can be used as clock inputs or outputs or general purpose
I/O. Along with the differential motion I/Os (P1, pins 1 – 4) of the LYNX Control Module, these I/O make up
the Group 1 signal set. Each signal pair is a 0 to 5VDC input or output. When used as an input or an output
a single ended or differential configuration is accommodated.
!
Hardware Specifications
!
Environmental Specifications
!
Mechanical Specifications
!
Power Requirements
!
Pin Assignments
!
Input Specifications
!
Input Filtering
!
Output Specifications
H a r d w a r e S p e c i f i c a t i o n s
E n v i r o n m e n t a l S p e c i f i c a t i o n
Ambient Operating Temperature .............................................. 0 to 50 degrees C
Storage Temperature ................................................................ -20 to 70 degrees C
Humidity .................................................................................. 0 to 90% non-condensing
M e c h a n i c a l S p e c i f i c a t i o n
0.39
(9.9)
4.39 max
(111.5)
3.75
(95.3)
0.9 max
(22.9)
Figure 10.1 : LYNX Differential I/O Module Dimensions