Modular l ynx system – Intelligent Motion Systems Modular LYNX System User Manual
Page 43

1 - 43
Modular L
YNX System
Modular LYNX System 12.05.2003
S e c t i o n 8
T h e LY N X C o n t r o l M o d u l e ( C o m b i n a t i o n )
S e c t i o n O v e r v i e w
The Control Module (Combination) (IMS Part # LX-CM200-000) offers the user of purchasing a LYNX
Control Module with 3 differential I/O Channels and 6 Isolated I/O lines instead of the standard 2 Isolated
I/O groups. This section will cover:
!
Hardware Specifications
!
Environmental Specifications
!
Mechanical Specifications
!
Power Requirements
!
Connection Overview
!
LED Indicators
!
Pin Assignments
!
Switch Assignments
H a r d w a r e S p e c i f i c a t i o n s
E n v i r o n m e n t a l S p e c i f i c a t i o n s
Ambient Operating Temperature .............................................. 0 to +50 degrees C
Storage Temperature ................................................................ -20 to +70 degrees C
Humidity .................................................................................. 0 to 90% non-condensing
M e c h a n i c a l S p e c i f i c a t i o n
Figure 8.1: LYNX Control Module (Combination) Dimensions
0.41
(10.4)
2.93
(74.4)
3.75 max
(95.3)
0.29
(7.4)
2.13
(54.1)
2.71 max
(68.8)
1.52 max
(38.6)
0.39
(9.9)
4.39 max
(111.5)
NOTE: All dimensions nominal unless otherwise specified.
13-
13+
14-
14+
17-
17+
21
22
23
24
25
26
IG
21
22
23
24
25
26
Dimensions in Inches (mm)