Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12

B. Rear Vent

CAUTION! Risk of Cuts, Abrasions or Flying Debris.

Wear protective gloves and safety glasses during instal-

lation. Sheet metal edges are sharp.
NOTICE: Once appliance is set up for top or rear venting,

it CANNOT be changed at a later time.

Figure 9.7 Fold the tabs toward the center of the seal

cap (90º) and remove the insulation gasket.

Figure 9.8 Cut the metal retaining band and fold the

sides out.

Figure 9.9 Fold the center parts of the retaining band out

and use to remove the seal cap.

Figure 9.10 Discard the vent cap, remove and discard

the insulation basket.

NOTICE: Once the seal cap has been removed it CANNOT

be reattached.

Figure 9.6 To attach the first section of vent pipe, make

sure to use the fiberglass gasket in the manual bag to seal

between the first vent component and the outer fireplace

wrap. Use 2 self tapping screws to secure the gasket to

the outer wrap.
Secure the first section of venting to the fireplace by screw-

ing through the two straps left over from cutting the seal

cap strap in step 2.