Warning, Top vent - horizontal termination, Top vent - horizontal termination one elbow – Heat & Glo Fireplace 8000CL-IPI-S User Manual

Page 26: E. vent diagrams

background image

Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12

26

H

1

V

1

Figure 7.3

Top Vent - Horizontal Termination

Top Vent - Horizontal Termination

One Elbow

Note: For corner installations: A 6 inch (152

mm) section of straight pipe may need to

be attached to the appliance before a 90º

elbow, to allow the vent pipe to clear the top

standoffs.

6000CL-IPI

V

1

Minimum

H

1

Maximum

Elbow only

2 ft

610 mm

6 in.

152 mm

6 ft.

1.8 m

1 ft.

305 mm

11 ft.

3.3 m

1-1/2 ft.

457 mm

18 ft.

5.5 m

2 ft.

1.2 m

25 ft.

7.6 m

V

1

+ H

1

= 40 ft. (12.2 m) Maximum

H

1

= 25 ft. (7.6 m) Maximum

Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles

between ceiling firestops.
• ALWAYS maintain specified clearances around

venting and firestop systems.

• Install wall shield and ceiling firestops as speci-

fied.

Failure to keep insulation or other material away

from vent pipe may cause fire.

Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal

SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal

Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-

SS termination caps on top vented fireplaces, a
6 inch minimum vertical vent section is required
before installing first elbow.

WARNING

WARNING

E. Vent Diagrams

Note: The 6000/8000 series fireplaces can adapt to SLP series

vent pipe, if desired.

When venting off the top of the unit, use a DVP-2SL adapter and a

minimum 48 inch vertical section of SLP series vent pipe.
A DVP-SLP24 adapter may also be used with a 24 inch vertical

section of SLP series vent pipe.
After the 48 inch vertical section, the venting table rules must be

followed. The first 48 inch

vertical section is NOT counted as part

of the vertical components in the table. It is still counted as part of

the overall maximum run. All venting table rules for the vent run

must still be followed.

8000CL-IPI

V

1

Minimum

H

1

Maximum

Elbow only

2 ft.

610 mm

6 in.

152 mm

2 ft.

610 mm

1 ft.

305 mm

5 ft.

1.5 m

1-1/2 ft.

457 mm

10 ft.

3.0 m

2 ft.

610 mm

18 ft.

5.5 m

2-1/2 ft.

762 mm

22 ft

6.7 m

V

1

+ H

1

= 40 ft. (12.2 m) Maximum

H

1

= 22 ft. (6.7 m) Maximum