D. burner identification/verification – Heat & Glo Fireplace 8000CL-IPI-S User Manual
Page 17

17
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
BASE REFRACTORY
Figure 3.6 Valve Assembly Removal
Note: The base refractory must be
removed to access screws.
Figure 3.5 Base Refractory Removal
D. Burner Identification/Verification
The burner may be accessed for identification and veri-
fication purposes. This task should be performed by a
qualified service technician. The base refractory, valve
plate, refractory panels and grate do not need to be re-
moved to access the burner assembly. The logs and fi-
ber burner top need to be removed to access the burner.
Disconnect the pilot from the burner before removal. See
Figure 3.7 for burner identification chart. Notch patterns
are located on bottom side of burner.
NOTCH LOCATION
NG LP
6000C
6000CL
6000CLX
6000CBV
8000C
8000CL
8000CLX
8000CBV
Figure 3.7 Burner Identification