Operating overview 2-25 – HP 2500C Series User Manual
Page 83

Operating Overview 2-25
139
DEFERRED_ERROR_TRAP
Error happened during power up but printer recovered
Printer error-trapped in a previous lifetime.
141
NVM_ERR_NOT_INIT
Not used
Attempt to read/write before init.
142
NVM_ERR_GENERIC
Not used
Non-specific NVM error.
143
NVM_ERR_DEVICE_ABSENT
NVM errors Reset printer =>Replace logic PCA
Requested memory device did not respond.
144
NVM_ERR_WRITE
NVM errors Reset printer =>Replace logic PCA
Protocol error on write operation to NVM.
145
NVM_ERR_READ
NVM errors Reset printer =>Replace logic PCA
Protocol error on read operation to NVM.
146
NVM_ERR_READBACK
NVM errors Reset printer =>Replace logic PCA
Failed readback/verify after write.
147
NVM_ERR_DATA_NOT_VALID
NVM errors Reset printer =>Replace logic PCA
Device works OK.
148
NVM_ERR_UNKNOWN_TAG
NVM errors Reset printer =>Replace logic PCA
Data tag invalid.
149
NVM_ERR_UNKNOWN_FORMAT
NVM errors Reset printer =>Replace logic PCA
Chip functions but has invalid format.
151
NVM_ERR_BAD_CHIP_TAG
Penhead and cartridge errors –Not used
Acumen's chip tag unrecognized.
152
NVM_ERR_BAD_FAMILY
Penhead and cartridge errors –Not used
Acumen's family ID unrecognized.
153
NVM_ERR_BAD_COLOR
Penhead and cartridge errors –Not used
Acumen's color code did not match device ID.
154
NVM_ERR_TSR_VALUE
Penhead and cartridge errors –Not used
Acumen TSR value = 0.
155
NVM_ERR_DROP_VALUE
Penhead and cartridge errors –Not used
Acumen drop volume = 0.
156
NVM_ERR_BAD_TOKEN
Penhead and cartridge errors –Not used
Token area failed zero-write self test.
157
NVM_ERR_BAD_WRITE_PROT
Penhead and cartridge errors –Not used
Write-protect area failed self test.
158
NVM_ERR_BAD_MODEL_NUM
Penhead and cartridge errors –Not used
Acumen Model Number field out of range.
159
NVM_ERR_INCOMPAT_INK
Penhead and cartridge errors –Not used
Non-approved bit and "JETSERIES".
161
NVM_ERR_BAD_MFG_WEEK
Penhead and cartridge errors –Not used
Mfg week > 51.
162
NVM_ERR_SPARE
Penhead and cartridge errors –Not used
Previously was Gas Gauge Gap.
163
NVM_ERR_POOL_ALLOC_FAIL
System recources – Reset printer
No memory to allocate pool from.
164
NVM_ERR_ACU_BAD_SIZE
Penhead and cartridge errors –Not used
Token Write-protected or Scratchpad size = 0.
165
NVM_ERR_DUPLICATE_TAG
Penhead and cartridge errors –Not used
Two identical tags were found in an Acumen chip.
166
NVM_ERR_TOKEN_MISLOC
Penhead and cartridge errors –Not used
Status superfield not located in token area.
167
NVM_ERR_I2C_CONF_FAIL
Bus used for connecting devices on the PCA experiences error.
Reset Printer => Replace PCA
A failure was detected on the serial bus used to access NVM
devices (I2C bus). The following extended error codes apply :
001 = STUCK_LO_SDA
002 = STUCK_HI_SDA
004 = STUCK_LO_SCL
005 = STUCK_LO_SCL + STUCK_LO_SDA
006 = STUCK_LO_SCL + STUCK_HI_SDA
008 = STUCK_HI_SCL
009 = STUCK_HI_SCL + STUCK_LO_SDA
010 = STUCK_HI_SCL + STUCK_HI_SDA
Memory Manager
171
MM_PROC_WAITING
Not used
Memory Manager error traps.
172
MM_SIGNAL_ERR
Not used
173
MM_MAX_WAIT_ERR
Not used
MM debug = 0.