Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

9

Î

For all side wall horizontally vented gas fueled equipment

installed in every dwelling, building or structure used in

whole or in part for residential purposes, including those

owned or operated by the Commonwealth and where the

side wall exhaust vent termination is less than seven (7)

feet above finished grade in the area of the venting, includ-

ing but not limited to decks and porches, the following re-

quirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented

gas fueled equipment, the installing plumber or gasfitter

shall observe that a hard wired carbon monoxide detector

with an alarm and battery back-up is installed on the floor

level where the gas equipment is to be installed. In addi-

tion, the installing plumber or gasfitter shall observe that a

battery operated or hard wired carbon monoxide detector

with an alarm is installed on each additional level of the

dwelling, building or structure served by the side wall hori-

zontal vented gas fueled equipment. It shall be the respon-

sibility of the property owner to secure the services of qual-

ified licensed professionals for the installation of hard wired

carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu-

eled equipment is installed in a crawl space or an attic, the

hard wired carbon monoxide detector with alarm and bat-

tery back-up may be installed on the next adjacent floor

level.

In the event that the requirements of this subdivision can

not be met at the time of completion of installation, the

owner shall have a period of thirty (30) days to comply with

the above requirements; provided, however, that during said

thirty (30) day period, a battery operated carbon monoxide

detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance

with the above provisions shall comply with NFPA 720 and

be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently

mounted to the exterior of the building at a minimum height

of eight (8) feet above grade directly in line with the ex-

haust vent terminal for the horizontally vented gas fueled

heating appliance or equipment. The sign shall read, in

print size no less than one-half (1/2) inch in size,

“GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-

STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally

vented gas fueled equipment shall not approve the installa-

tion unless, upon inspection, the inspector observes carbon

monoxide detectors and signage installed in accordance with

the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1

through 4:
• The equipment listed in Chapter 10 entitled “Equipment

Not Required To Be Vented” in the most current edition

of NFPA 54 as adopted by the Board; and

• Product Approved side wall horizontally vented gas fu-

eled equipment installed in a room or structure sepa-

rate from the dwelling, building or structure used in whole

or in part for residential purposes.

MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall hor-

izontally vented gas equipment provides a venting system

design or venting system components with the equipment,

the instructions provided by the manufacturer for installa-

tion of the equipment and the venting system shall include:
• Detailed instructions for the installation of the venting

system design or the venting system components; and

• A complete parts list for the venting system design or

venting system.

Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall

horizontally vented gas fueled equipment does not provide

the parts for venting the flue gases, but identifies “special

venting systems”, the following requirements shall be sat-

isfied by the manufacturer:
• The referenced “special venting system” instructions shall

be included with the appliance or equipment installation

instructions; and

• The “special venting systems” shall be Product Approved

by the Board, and the instructions for that system shall

include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap-

proved side wall horizontally vented gas fueled equipment,

all venting instructions, all parts lists for venting instruc-

tions, and/or all venting design instructions shall remain

with the appliance or equipment at the completion of the

installation.
See Gas Connection section for additional Common-

wealth of Massachusetts requirements.

NOTE: The following requirements reference various

Massachusetts and national codes not contained in

this document.

Requirements for the Commonwealth of

Massachusetts