Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

15

Figure 5. Vent System Components and Termination Kits

Step 3. Installing the Vent System

A. Vent System Approvals

These models are approved to use DVP-series direct vent

pipe components and terminations (see Figures 4 and 5).

Approved vent system components are labeled for identifi-

cation. This pipe is tested and listed as an approved com-

ponent of the fireplace. The pipe is tested to be run inside

an enclosed wall. There is no requirement for inspection

openings at each joint within the wall. There is no required

pitch for horizontal vent runs.

NO OTHER VENTING SYS-

TEMS OR COMPONENTS MAY BE USED.
Detailed installation instructions are included with each vent

termination kit and should be used in conjunction with this

Installers Guide.

The flame and ember appearance may vary based on the type

of fuel burned and the venting configuration used.

Identifying Vent Components
The vent systems installed on this gas fireplace may in-

clude one, two, or three 90° elbow assemblies. The rela-

tionships of vertical rise to horizontal run in vent configura-

tions using 90° elbows

MUST BE strictly adhered to. The

rise to run relationships are shown in the venting drawings

and tables. Refer to the diagrams on the next several pages.

NOTE: Two 45° elbows may be used in place of one

90° elbow. Rise to run ratios in the vent system must

be followed if 45° elbows are used.
This model has vent starting collars on both the top and the

back of the unit. Depending upon the installation, decide

which

ONE set of starting collars will be used to attach the

vent system. The starting collar sealing cap must remain

on the starting collar

NOT used.

Terminations Kits

(For use on IPI units only)

(Required to have a minimum of 3

feet of vertical in the vent system)

DVP-TV

PVK-80

DVP-TVHW

DVP-TRAP

DVP-TB1

SERIES

HORIZONTAL

TERMINATION

VERTICAL

TERMINATION

STORM COLLAR

ROOF FLASHING

PIPE LENGTH

CEILING

FIRESTOP

90 DEGREE

ELBOW

WALL FIRESTOP