beautypg.com

Venting with two (2) 90° elbows, Venting with two (2) 90, Elbows v ft. h + h – Heat & Glo Fireplace 6000TR-OAK User Manual

Page 15: Ft.)

background image

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

19

Figure 14. Venting with Two 90° Elbows

VENTING WITH TWO (2)

90° ELBOWS

V

H

H + H

1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

5´ MAX. (1.52m)

2´ MIN. (610 mm)

4´ MAX. (1.22 m)

10´ MAX. (3.1m)

3´ MIN. (914 mm)

6´ MAX. (1.86 m)

15´ MAX. (4.65m)

4´ MIN. (1.22 m)

8´ MAX. (2.48 m)

20´ MAX. (6.2m)

V+H+H

1

= 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H

1

= 20´ MAX. (6.2m)

Figure 15. Venting with Two 90° Elbows

VENTING WITH TWO (2) 90

o

ELBOWS

V FT.

H + H

1

(FT.)

1' MIN. (305mm)

5´ MAX. (1.52m)

2' MIN. (610mm)

10´ MAX. (3.1m)

3' MIN. (914mm)

15´ MAX. (4.65m)

4' MIN. (1.22m)

20´ MAX. (6.2m)

V+H+H

1

= 40' MAX.(12.4m) H+H

1

= 20´ MAX. (6.2m)

V+V

1

+H= 40' MAX.(12.4m)

H

1

V

H

V

V

1

H

Î

H

1

H

V