Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

16

Figure 6.

Straight Up Vertical Venting

STRAIGHT UP

VERTICAL VENTING

V (FT.)

40' MAX. (12.4 M)

CAP

V

Flue Restrictor Instructions

1. Remove Exhaust Shield using a 1/4” nut driver by

removing the four screws securing it in place (see

Figure 7).

Figure 8. Flue Restrictor

BREAK

HERE

Figure 7

EXHAUST

SHIELD

FLUE

RESTRICTOR

2. Break the Flue Restrictor into two pieces. Do this

by bending the part back and forth until it breaks
(see Figure 8).

NOTE: On vertical venting

configurations over 10 feet

install the flue restrictor

(385-128). See flue restric-

tor installation instructions.