beautypg.com

Heat & Glo Fireplace 6000TR-OAK User Manual

Page 17

background image

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

21

VENTING WITH THREE (3) 90° ELBOWS

V (FT.)

H + H

1

(FT.)

1' MIN. (305mm)

5' MAX. (1.52m)

2' MIN. (610mm)

10' MAX. (3.1m)

3' MIN. (914mm)

15' MAX. (4.65m)

4' MIN. (1.22m)

20' MAX. (6.2m)

NOTE: H + H

1

= 20' MAX. (6.2m)

V + V

1

+ H + H

1

= 40' MAX. (12.4m)

V + V

1

(FT.)

H + H

1

(FT.)

1' MIN. (305mm)

5' MAX. (1.52m)

2' MIN. (610mm)

10' MAX. (3.1m)

3' MIN. (914mm)

15' MAX. (4.65m)

4' MIN. (1.22m)

20' MAX. (6.2m)

H +H

1

= 20' MAX. (6.2m)

NOTE:

V+V

1

+H +H

1

= 40' MAX. (12.4m)

Figure 17. Venting with three 90° elbows

V

H

H

1

V

1

V

H

H

1

V

1

О