beautypg.com

Heat & Glo Fireplace 6000TR-OAK User Manual

Page 16

background image

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

20

Figure 16. Venting with three 90° elbows

VENTING WITH THREE (3) 90° ELBOWS

1´MIN. (305mm)

2´MAX. (610mm)

5´MAX. (1.52m)

2´MIN. (610mm)

4´MAX. (1.22m)

10´MAX. (3.1m)

3´MIN. (914mm)

6´MAX. (1.86m)

15´MAX. (4.65m)

4´MIN. (1.22m)

8´MAX. (2.48m)

20´MAX. (6.2m)

V+H+H

1

+H

2

= 40

´

MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H

1

+H

2

= 20´ MAX. (6.2 m)

V

H

H + H

1

+ H

2

1´MIN. (305mm)

2´MAX. (610mm)

5´MAX. (1.52m)

2´MIN. (610mm)

4´MAX. (1.22m)

10´MAX. (3.1m)

3´MIN. (914mm)

6´MAX. (1.86m)

15´MAX. (4.65m)

4´MIN. (1.22m)

8´MAX. (2.48m)

20´MAX. (6.2m)

V

1

+V+H+H

1

= 40

´

MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H

1

= 20´MAX.(6.2 m)

V H H + H

1

H

V

H

1

V

1

Î

H

H

1

2

V

H