beautypg.com

B. installing vent components, Dvp pipe – Heat & Glo Fireplace 6000TR-OAK User Manual

Page 18

background image

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

22

!

B. Installing Vent Components

After determining which set of starting collars will be used

(top or rear), follow venting instructions accordingly.
Venting Out the Rear Vent

Remove the installed rear seal cap from the rear starting

collars by cutting the strap at each end. (see Figure 18).

Follow the vent configuration tables accordingly.
Remove the insulation from the

REAR five inch flue, pull

the heat shield out from outside of the firebox.

WARNING: THE TOP HEAT SHIELD (INSIDE

THE FIREBOX) MUST REMAIN ATTACHED IF

THE VENT SYSTEM IS ATTACHED TO THE

REAR STARTING COLLARS. SEE FIGURE 18.

Venting Out the Top Vent

Remove the two screws in the top vent collar seal cap and

remove the top vent collar seal cap and two pieces of in-

sulation inside the top two starting collars (See Figure 18).
Remove the heat shield from inside the

TOP five inch flue

from outside of the firebox.
The glass must be taken off again for positioning the logs

when the unit is finally installed in place and finished around

it. Re-install the glass door. Attach vent system to the top

starting collars.

WARNING: THE REAR VENT COLLAR SEAL

CAP MUST REMAIN ATTACHED TO THE REAR

VENT COLLARS IF THE VENT SYSTEM IS AT-

TACHED TO THE TOP STARTING COLLARS.
WARNING: FAILURE TO REMOVE INSULATION

IN THE SET OF COLLARS YOU ARE USING

COULD CAUSE A FIRE.
WARNING: YOU MUST LEAVE THE INSULATION

IN PLACE IN THE SET OF COLLARS YOU ARE

NOT USING.

Figure 18

CUT

HERE

Venting Out Rear

Venting Out Top

!

!

!

HEAT

SHIELD

DISCARD

INSULATION

and

HEAT SHIELD

HEAT

SHIELD

INSULATION

DISCARD BOTH

PIECES and

HEAT SHIELD

SEAL

CAP

SEAL

CAP

Cut the seal cap

strap and remove white

gasket material.

1. Attach the First Vent Component to the

Starting Collars
To attach the first vent component to the starting collars of

the fireplace:
• Make sure that the fiberglass gasket supplied in the

manual bag seals between the first 8 inch (203mm)

vent component and the outer fireplace wrap. Using 2

self-tapping screws from the manual bag secure that

gasket to the outer wrap (see Figure 19).

Figure 19. Fiberglass Gasket

FIRST VENT

COMPONENT

FIBERGLASS

GASKET

OUTER

WRAP

DVP PIPE:

2. Assembling Vent Sections
Refer to Cinch Pipe and Termination Cap installation in-

structions.

1. Attaching the Venting to the Fireplace
Refer to Cinch Pipe and Termination Cap installation in-

structions.

!

WARNING: ENSURE THAT THE FIBERGLASS

GASKET SUPPLIED WITH THE FIREPLACE

SEALS BETWEEN THE FIRST VENT COMPONENT

AND THE OUTER FIREPLACE WRAP.

If the installation is for a termination cap attached directly

to the fireplace, skip to the sections,

Install Firestops and

Vent Termination.

This manual is related to the following products: