Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer. The trans-

former plugs into the junction box and the two leads plug

into the green control module (see Figure 37).
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the

factory installed junction box. Maintain correct polarity when

wiring the junction box.

WARNING: DO NOT CONNECT 110-120 VAC

TO THE GAS CONTROL VALVE OR THE AP-

PLIANCE WILL MALFUNCTION AND THE

VALVE WILL BE DESTROYED.

Operation using Battery Power
This fireplace has an optional battery operation. The sys-

tem is fully functional with the use of two “D” size batteries

without ordinary 110-120 VAC power.
Wiring to the battery pack should be left disconnected in

order to conserve battery life. In the case of a loss of power,

!

!

Figure 37. Intermittent Pilot Ignition (IPI) Wiring Diagram

simply connect red and black wire leads to activate battery

power (connect red to red, black to black). The fireplace

can be used as necessary. Once power (110 VAC) is re-

stored, disconnect red and black wire leads to extend bat-

tery life.

Optional Accessories
Optional remote control kits require that 110-120 VAC be

wired to the factory installed junction box before the fire-

place is permanently installed.

Wall Switch
Position the wall switch in the desired position on a wall.

Run a maximum of 25 feet (7.8 m) or less length of 18

A.W.G. minimum wire and connect it to the fireplace ON/

OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC

TO THE WALL SWITCH OR THE CONTROL

VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-

TION WHEN SERVICING CONTROLS. WIRING ERRORS

CAN CAUSE IMPROPER AND DANGEROUS OPERA-

TION. VERIFY PROPER OPERATION AFTER SERVICING.

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

G

RN

OR

G

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF SWITCH

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1-#5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BRN

BRN

VALVE

PLUG IN

GROUND TO

FIREPLACE

CHASSIS