Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

26

V

= VENT TERMINAL

X

= AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

Figure 29. Minimum Clearances for Terminations

A

= 12" ....................... clearances above grade, veran-

da, porch, deck or balcony

B

= 12" ....................... clearances to window or door

that may be opened, or to per-

manently closed window.

D*

= 18" ....................... vertical clearance to unventilat-

ed soffit or to ventilated soffit lo-

cated above the terminal

*30” ...................... for vinyl clad soffits and below

electrical service

F

= 9" ........................ clearance to outside corner

G

= 6" ......................... clearance to inside corner

H

= 3 ft. (Canada) ...... not to be installed above a gas

meter/regulator assembly within

3 feet (90cm) horizontally from the

center-line of the regulator

I

= 3 ft. (U.S.A.)

6 ft. (Canada) ...... clearance to gas service regu-

lator vent outlet

J

= 9" (U.S.A.)

12" (Canada) ........ clearance to non-mechanical air

supply inlet to building or the

combustion air inlet to any other

appliance

K

= 3 ft. (U.S.A.)

6 ft. (Canada) ......... clearance to a mechanical

air supply inlet

L** = 7 ft. ......................... clearance above paved

sidewalk or a paved driveway

located on

public property

M*** = 18" ......................... clearance under veranda,

porch, deck, balcony or over-

hang

42” ......................... vinyl

N

= 6” ........................... non-vinyl sidewalls

12” ......................... vinyl sidewalls

P

= 8 ft.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE

INSTALLED.

** a vent shall not terminate directly above a sidewalk or paved

driveway which is located between two single family dwellings

and serves both dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open on

a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feet

above a sidewalk, driveway, deck, porch, veranda or balcony, use of

a listed cap shield is suggested.

NOTE 2: Termination in an alcove space (spaces open only on one side

and with an overhang) are permitted with the dimensions specified for

vinyl or non-vinyl siding and soffits.

1. There must be 3 feet minimum

between termination caps.

2. All mechanical air intakes within 10 feet

of a termination cap must be a minimum of 3 feet below the termination

cap.

3. All gravity air intakes within 3 feet of a termination cap must be

a minimum of 1 foot below the termination cap.

M

N

P

R

Q

(See Note 1)

(See Note 1)

(See Note 2)

S = 6" .......................... clearance from sides of elec-

trical service

T = 12" ......................... clearance above electrical

service

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

Q

MIN

R

MAX

1 cap

3 feet

2 x Q

ACTUAL

2 caps

6 feet

1 x Q

ACTUAL

3 caps

9 feet

2/3 x Q

ACTUAL

4 caps

12 feet

1/2 x Q

ACTUAL

Q

MIN

= # termination caps x 3 R

MAX

= (2 / # termination caps) x Q

ACTUAL

(See Note 5)

(See Note 5)

Electrical

Service

V

S

V

S

V

T

D*

V

NOTE 3: Local codes or regulations may require different

clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to

doors or other traffic areas.
NOTE 5: Location of the vent termination must not interfere with

access to the electrical service.
WARNING: In the U.S: Vent system termination is NOT permitted

in screened porches. You must follow side wall, overhang and

ground clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened

porches. Vent system termination is permitted in porch areas

with two or more sides open. You must follow all side walls,

overhang and ground clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper perfor-

mance of the fireplace when the venting system does not meet

these requirements.

D

E

B

L

v

v

v

v

v

v

v

v

B

B

A

H

M

X

J or K

I

A

G

F

U.S.

(3 FT)

B