Heat & Glo • RED40, RED40ST • 2155-900 Rev. P • 10/12

24

Figure 7.4

Top Vent - Horizontal Termination

Venting with 1 elbow

H

1

V

1

Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.

WARNING

Note: Use DVP Series
components only.

V

1

Minimum

H

1

Maximum

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

6 ft.

1829

3 ft.

914 mm

9 ft.

2743

4 ft.

1219 mm

12 ft.

3658

5 ft.

1524 mm

15 ft.

4572

6 ft.

1829 mm

18 ft.

5486

7 ft.

2134 mm

21 ft.

6401

8 ft.

2438 mm

24 ft.

7315

V

1

+ H

1

= 63 ft. (19.2 m) Maximum

Note: 12 inches minimum vertical is
required prior to attaching any elbow
to the appliance.