B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fi re.

Figure 13.12 Clearances To Combustibles Mantels Or Other

Combustibles Above Appliance

Note: All
measurements
in inches.

Figure 13.13 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Figure 13.14 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

5

6

7

8

9

10

3

4

5

12

11

10

9

8

7

6

TOP OF HOOD OR FIREPLACE OPENING

4

12

13

11

32

CEILING

3 FT. MAXIMUM

TOP VIEW

2-7/8 IN.

MINIMUM

1/2 IN.
MINIMUM

5-3/8 IN.
MINIMUM

3 IN.
MINIMUM

Note: Clearance from
opening to perpendicular wall.

UNLIMITE

Note: Clearance from opening
to perpendicular wall.

Figure 13.15 Non-Combustible Zone

1/2 in. SHEETROCK
OR COMBUSTIBLE
MATERIAL

3-1/2 in.

1/2 in.

NON-COMBUSTIBLE ZONE