Henny Penny 600 EN User Manual
Page 17
Model 500/561/600
Timer Programming
1.
Anytime the cook time is displayed, press under the appropri-
ate display to change the cook time.
Set-Point Temperature Programming
1.
Press
once to view the actual shortening temperature and
press
again to view the set-point temperature.
2.
While the set-point temperature is in the display, press
to change the set-point temperature.
If “LOCK” shows in display when pressing ,
the controls are locked and must be unlocked before changing
the time or set-point temperature. See C1000 Special
Programming Section.
3-6. C1000 PROGRAMMNG
INSTRUCTIONS
3-7. C1000 SPECIAL
PROGRAMMNG
Special Programming is used to set the items below:
Fahrenheit or Celsius
Initialize System
Lock or Unlock Controls
Fryer Type – Open or Pressure
Heat Source – Electric; Gas w/electronic ignition
Vat Type - Full or Split
Oil Type - Solid or Liquid
1. To enter Special Programming, turn off power switch
(either side). Press and hold and turn the power
switch back on.
2. “SPEC” “PROG” followed by, “DEG” “°F” or “°C”.
Use
to choose “°F” or “°C”.
3. Press
and “INIT” shows in the display.
Press and hold
and display shows “In-3”,
“In-2”, “In-1” followed by “Init Sys” “DONE DONE”. The
controls now are reset to factory parameters, the time set to
0:00 and temperature 190°F or 88°C.
4. Press
and “LOCK” or “UNLOCK” shows in the dis-
plays. Use
to choose “LOCK” or “UNLOCK.
5. Press
and “FRYR” shows in left display and the right
display should show “PRES”. Use to change from
“OPEN” to “PRES” if needed.
1209
3-17