B.1
North American Classification of Hazardous
Locations,
Continued
Examples
Given the above criteria, the following examples are made:
• A Class III, Division 1 location is a location in which easily
ignitable fibers or material processing combustible flyings are
handled, manufactured or used.
• A Class III, Division 2 location is a location in which easily
ignitable fibers are stored or handled.
Groups
Flammable gases, vapors and ignitable dusts, fibers and flyings are
classified into one of the following groups according to the energy
required to ignite the most easily-ignitable mixture within air.
Class I
Group
Description of Atmosphere
A
Atmospheres containing acetylene.
B
Atmospheres containing hydrogen, fuel and combustible
process gases containing more than 30 percent hydrogen by
volume, or gases or vapors of equivalent hazard
C
Atmospheres such as ethyl ether, ethylene, or gasses or vapors
of equivalent hazard.
D
Atmospheres such as acetone, ammonia, benzene, butane,
cyclopropane, ethanol, gasoline, hexane, methanol, methane,
natural gas, naphtha, propane or gases or vapors of equivalent
hazard.
Class II
Group
Description
E
Atmospheres containing combustible metal dusts including
aluminum, magnesium, and their commercial alloys, and other
metals of similarly hazardous characteristics.
F
Atmospheres containing combustible carbonaceous dusts
including carbon black, charcoal, coal or other dusts that have
been sensitized by other materials so that they present an
explosion hazard.
G
Atmospheres containing combustible dusts not included in
Group E or F, including flour wood, grain, and other dusts of
similarly hazardous characteristics.