beautypg.com

Ii 3 g eex na iic atex, Certificate of manufacturer – Honeywell ST 3000 User Manual

Page 123

background image

10/04

34-ST-99-36 (Addendum to 34-ST-33-39)

9 of 10

Certificate of Manufacturer

II 3 G EEx nA IIC ATEX

This certificate applies to the following equipment:

ST 3000 Smart Pressure Transmitters, Series 100 and 900, Release 100 and 900, 4-20 mA,
DE, HART, and FOUNDATION

TM

Fieldbus (per attached list)

This equipment has no arcing or sparking parts and no ignition-capable hot surfaces, and therefore conforms to
Clause 6.3.1.3 of VDE 0165/2.91, IEC 60079-14, and EN 50021 for operation in Zone 2 hazardous areas
providing that the following conditions are observed. The equipment contains no intrinsically safe or energy-
limiting components. The listed equipment are 2-wire devices that receive their power and signal carrier from
the same 4-20 mA signal current or Fieldbus supply. In normal operation, the maximum current supply is 23
mA for

≤ 4-20 mA analog, DE or HART, and ≤ 260 mA for Fieldbus

.

Conditions for the application of the above equipment in Zone 2 hazardous areas:

1. The installation of this equipment in Zone 2 hazardous areas must comply with VDE specification 0165, IEC

60079-14, EN 50021 and/or valid national standards for installation and operation.

2. Before commissioning this equipment, it must be verified that the power supply voltage cannot exceed the 42

Vdc maximum for 4-20 mA analog, DE and HART equipment, and 24 Vdc for Fieldbus equipment.

3. The electronic assemblies in these units are non-repairable items and if faulty, must be replaced. The

electrical power supply must be switched off before any replacement and during any time that the wiring
terminations are being connected or disconnected.

4. The technical data supplied by the manufacturer must be adhered to.

Specifications for Use in Zone 2

4-20 mA / DE / HART

Fieldbus

Supply Voltage:

11 – 42 Vdc

10 – 24 Vdc

Supply Current:

23 mA

260 mA

Ambient temperature limits:

–50 to 93ºC

Temperature Classification:

T6 at Ta

≤ 78ºC

T5 at Ta

≤ 93ºC

Manufacturing Location:

Honeywell Process Solutions
2500 West Union Hills Drive
Phoenix, Arizona 85053 USA


Honeywell International Inc.
Industrial Measurement & Control
1100 Virginia Drive
Fort Washington, PA 19034 USA

Frederick M. Kent

Standards & Approvals Engineer,

(ATEX

A

uthorized Person)

Issue Date:

25 June 2004