IGBT Test Method

The following procedure will check the inverter transistors (IGBTs) and diodes:

1. Disconnect input power to terminals [R, S, and T] and motor terminals [U, V, and W].

2. Disconnect any wires from terminals [+] and [RB] for regenerative braking.

3. Use a Digital Volt Meter (DVM) and set it for 1

Ω resistance range. You can check the

status of the charging state of terminals [R, S, T, U, V, W, RB, +, and –] of the inverter
and the probe of the DVM by measuring the charging state.

Table Legend – Almost infinite resistance:

≅ ∞ Ω Almost zero resistance: ≅ 0 Ω

NOTE: The resistance values for the diodes or the transistors will not be exactly the
same, but they will be close. If you find a significance difference, a problem may exist.

NOTE: Before measuring the voltage between [+] and [–] with the DC current range,
confirm that the smoothing capacitor is discharged fully, then execute the tests.

Part

DVM

Measured

Value

Part

DVM

Measured

Value

Part

DVM

Measured

Value

+

+

+

D1

[R]

+1

≅ ∞ Ω

D5

[S]

[N]

≅ 0 Ω

TR4

[U]

[–]

≅ 0 Ω

+1

[R]

≅ 0 Ω

[N]

[S]

≅ ∞ Ω

[–]

[U]

≅ ∞ Ω

D2

[S]

+1

≅ ∞ Ω

D6

[T]

[N]

≅ 0 Ω

TR5

[V]

[–]

≅ 0 Ω

+1

[S]

≅ 0 Ω

[N]

[T]

≅ ∞ Ω

[–]

[V]

≅ ∞ Ω

D3

[T]

+1

≅ ∞ Ω

TR1

[U]

[+]

≅ ∞ Ω

TR6

[W]

[–]

≅ 0 Ω

+1

[T]

≅ 0 Ω

[+]

[U]

≅ 0 Ω

[–]

[W]

≅ ∞ Ω

D4

[R]

[N]

≅ 0 Ω

TR2

[V]

[+]

≅ ∞ Ω

TR7

[RB]

[+]

≅ 0 Ω

[N]

[R]

≅ ∞ Ω

[+]

[V]

≅ 0 Ω

[+]

[RB]

≅ ∞ Ω

TR3

[W]

[+]

≅ ∞ Ω

[RB]

[–]

≅ 0 Ω

[+]

[W]

≅ 0 Ω

[–]

[RB]

≅ 0 Ω

[R]

[S]

[T]

TR1

TR2

TR3

[U]

[V]

[W]

[–]

D1

D2

D3

D4

D5

D6

+

[+] [RB]

[+1]

TR4

TR5

TR6

TR7