beautypg.com

Hitachi SJ200 Series User Manual

Page 157

background image

Using Intelligent Input Terminals

Oper

ations

and Monitor

ing

4–30

It is possible for the inverter to retain the frequency set from the [UP] and [DWN] termi-
nals through a power loss. Parameter C101 enables/disables the memory. If disabled, the
inverter retains the last frequency before an UP/DWN adjustment. Use the [UDC]
terminal to clear the memory and return to the original set output frequency.

Option

Code

Terminal

Symbol

Function Name

Input

State

Description

27

UP

Remote Control
UP Function (motor-
ized speed pot.)

ON

Accelerates (increases output frequency) motor
from current frequency

OFF

Output to motor operates normally

28

DWN

Remote Control
DOWN Function
(motorized speed
pot.)

ON

Decelerates (decreases output frequency) motor
from current frequency

OFF

Output to motor operates normally

29

UDC

Remote Control Data
Clear

ON

Clears the Up/down frequency memory

OFF

No effect on Up/down memory

Valid for inputs:

C001, C002, C003, C004,
C005, C006

Required settings:

A001 = 02

Notes:

This feature is available only when the frequency
command source is programmed for operator
control. Confirm A001 is set to 02.

This function is not available when [JG] is in use.

The range of output frequency is 0 Hz to the value
in A004 (maximum frequency setting).

The minimum ON time of [UP] and [DWN] is 50 ms.

This setting modifies the inverter speed from using F001 output frequency setting as a starting point.

1

2

3

4

5

6

L

PCS

Example (requires input configuration—
see page

3–41

):

See I/O specs on page

4–6

.

DWN UP