MFJ-1278B MULTI-MODE OPERATIONAL COMMANDS
SETUP
Mode: ALL Default: see table below
All possible baud rates and modem configurations are displayedon the SETUP menu. The
selected baud rates and modem configurations are also shown.
Anytime the MFJ-1278B default values are loaded the baud rate and modem default profile is
loaded as well. The defaults are shown in the below table:
Modem
Mode
Default Baud Rate/
Speed/ Format
P
VHF Packet
1200
H
HF Packet
300
V
VHF Baudot RTTY
45
H
HF Baudot RTTY
45
V
VHF Ascii RTTY
110
H
HF Ascii RTTY
110
C
CW
20 WPM
C
Memory Keyer
20 WPM
P
Wefax/Fax
3 (120 Lines/Min.)
P
SSTV
1 (8.5 Sec. format)
H
Amtor/Navtex
100
M
Multi-level FAX/SSTV
All Formats
The terminal baud rate and modem configurations may be changed by using the SETUP
command.
SFNL ON/OFF
Mode: AMTOR Default: OFF
SFNL controls whether the MFJ-1278B adds a new line character to "+?" and WRU.