beautypg.com

11 data out connector, 12 alarm connector, Data out connector -15 – Ericsson RX8000 Series User Manual

Page 47: Alarm connector -15, Table 2.12, Table 2.13

background image

Chapter 2

2.7.11

DATA OUT Connector

A data output interface may be used with either RS232 or
RS422 connector, as described below.

Table 2.12 DATA OUT Connector

Item Specification

Connector type

9-way, D-type, female

Connector designation DATA OUT

Pin

RS232

RS422

Pin-outs Pin

1

Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9

NC
TxD
RxD
NC
NC
NC
CTS
(RTS)
NC

HSD_CLK_A
NC
NC
NC
NC
HSD_CLK_B
NC
HSD_DATA_A
HSD_DATA_B

DATA OUT

2.7.12

ALARM Connector

All units provide an alarm relay connector supplying a
summary relay. Under user configuration, it is activated
whenever the unit detects an alarm, or the power is
switched off.

Table 2.13 ALARM Connector

ALARM RELAY

Item Specification

Connector type

9-way, D-type, female

Connector designation ALARM

Pin-outs

Pin 1 – Relay 1, Normally Closed
Pin 2 – Relay 2, Common
Pin 3 – Relay 1, Common
Pin 4 – Relay 3, Common
Pin 5 – Relay 1, Normally Open
Pin 6 – Relay 2, Normally Closed
Pin 7 – Relay 2, Normally Open
Pin 8 – Relay 3, Normally Closed
Pin 9 – Relay 3, Normally Open

EN/LZT 790 0005 R1A