3 asi out connector (rx8310/15/20 only), Asi out connector (rx8310/15/20 only) -11, Table 2.3 – Ericsson RX8000 Series User Manual
Page 43: Rf in connector -11, Table 2.4, Asi out connector -11, Cautions
Chapter 2
Cautions!
The receiver provides DC power (see Chapter 3, Front Panel Control for details of
menu option) via the active L-band input connector to drive an LNB. Do not connect
equipment other than an LNB to this connector. Failure to do this may result in
damage to the external equipment.
The F-type connector is not suitable for repeated connection and disconnection.
When intended for use in this way, fit a sacrificial connector and connect to it.
Table 2.3 RF IN Connector
Item Specification
Connector type
F-type 75
Ω female socket
Connector designation
RF IN 1
RF IN 2
RF IN 3
RF IN 4
LNB Power Supply
See Cautions! above.
Pin-outs Centre
Shield
Input
Ground/Chassis
2.7.3
ASI OUT Connector (RX8310/15/20 only)
The unit provides two coaxial ASI digital outputs
depending on the user selectable configuration.
Table 2.4 ASI OUT Connector
Item Specification
Connector type
BNC 75
Ω female socket
Connector designation
ASI OUT 1
ASI OUT 2
Pin-outs Centre
Shield
Output
Ground/Chassis
ASI OUT
EN/LZT 790 0005 R1A
2-11