beautypg.com

Synchronize clock function block sc01, Ez800/ezd control commands – Eaton Electrical PROFIBUS-DP EZ204-DP User Manual

Page 176

background image

For more information visit: www.EatonElectrical.com

EZ800/EZD Control Commands

MN05013001E

172

Synchronize clock function block SC01

Telegram structure

Table 108: Operand overview

Table 109: Index 0 – Bit IO

Byte

Meaning

Value (hex), sent by

Master

Slave

0

Toggle byte

J

page 94

1

Command: Read

92

Response:

Read successful

C2

Command

rejected

C0

2

Type

20

20

3

Instance

01

01

4

Index

J

Table 108

5 – 8

Data 1 – 4

00

depending on

index,

J

Table 109

Index
(hex)

Operand

Read

Write

00

Bit IO, J Table 109

×

01

Mode/Parameter

Bit 7 6 5 4 3

2

1

0

FB input Data 1

– – – – –

T

1

FB output Data 3

– – – – –

Q1

2

1) Trigger coil. If the coil is triggered (rising edge), the current

date, weekday and time of the sending station are automatically

sent to the NET network.

2) Status 1 if the trigger coil SC01T_ is also 1.