beautypg.com

Troubleshooting, Flash malfunction warning – Nikon 4804 R1 Wireless Close-Up Speedlight System User Manual

Page 128

background image

7

Troubleshooting

128

Flash malfunction warning

While the SB-R200 is used as a wireless remote flash unit, the red ready-light
rapidly blinks four times and stops for 0.5 sec. This cycle is repeated six times if
the flash unit receives a signal such as Non-TTL auto flash or Repeating flash.

Problems with the Commander SU-800 and the Remote
Speedlight SB-R200

Problem

Cause

Solution

The SB-R200
does not fire.

The SB-R200’s power is off.

Confirm that the red ready-light
comes on.

Different channel numbers are set
to the Commander (SU-800) and
the SB-R200.

Set the same channel number to
both flash units.

Different group names are set to
the Commander (SU-800, etc.) and
SB-R200.

Set the same group to both flash
units.

Control signal from the
Commander (SU-800, etc.) does
not reach the light sensor window
of the SB-R200.

Rearrange the position of the
SB-R200 so that the light from the
Commander reaches the SB-R200.

Vignetting occurs The shutter speed set is faster or

slower than the flash sync speed.

Set the shutter speed to the flash
sync speed.

Vignetting occurs with a wide
angle lens

Change the lens’ focal length.

Underexposure
occurs

Light from the flash unit enters the
camera lens or light sensor window
on the flash unit.

Rearrange the position of the
camera or flash unit so that the
light does not enter the lens or light
sensor window.

AF-Assist
Illuminator does
not turn on.

The SU-800 is set to close-up
mode.

In the close-up mode, the
AF-Assist Illuminator on the
SU-800 does not illuminate.
However, camera’s AF-assist
illuminator turns on.

Camera’s focus mode is set to
“AF-C”.

Set camera’s focus mode to
“AF-S”.