4.7 Communications Cell Settings
4-23
4
4.7.3
Write Cells
Right-click the desired cell and select
Cell Communications Setup - YASKAWA Cell Set-
ting
from the pop-up menu. The
Cell Setting
Dialog Box will be displayed as shown below.
(Shown with default settings.)
The values that are displayed in the dialog box are the previously set values.
1. Check that the
R/W selection
Option is set to
Write
.
2. Set the cell settings so that the desired controller data can be written.
3. When the settings have been completed, click the
OK
Button.
4. The dialog box will close and the cell setting will be saved.
5. If the address setting is incorrect, a message box will appear.
6. Cells that are set to write data will be outlined, and a
Write
Button will be added next to
the cell.
• Logical Port
Select the logical port that connects to the desired controller from the
Communica-
tions Ports
List in the communications driver settings.
• Device
Select the desired controller.
The device name that was assigned in the controller settings will be displayed here.
• CPU No.
The CPU number can be specified by clicking the
Detail
Button. If the MP920 or
CP-9200SH is used in a multi-CPU environment, use CPU number 1 or 2. Other con-
trollers should be set to 1.
• Addressing Scheme
Specifies the addressing scheme.
Register Number
and
Reference Number
can be selected. The register type and
address depend on the addressing scheme.
Address