ProSoft Technology MVI69-ADM User Manual
Page 253

MVI-ADM ♦ 'C' Programmable
Serial Port Library Functions
'C' Programmable Application Development Module
Developer's Guide
ProSoft Technology, Inc.
Page 253 of 342
February 20, 2013
MVIsp_Puts
Syntax
int MVIsp_Puts(int comport, BYTE *str, BYTE term, int *len, DWORD timeout);
Parameters
comport
port to which data is to be sent
str
string of characters to be sent
term
termination character of string
len
pointer to BYTE to receive number of characters sent
timeout
amount of time to wait to send character
Description
This function transmits a string of characters across a serial port. comport must
be previously opened with MVIsp_Open.
str is a pointer to an array of characters (or is a string) to be sent.
MVIsp_Puts sends each char in the array str to the serial port until it encounters
the termination character term. Therefore, the character array must end with the
termination character. The termination character is not sent to the serial port.
All data sent to a port is queued before transmission across the serial port.
Therefore, some delay may occur between the time this function returns and the
actual time that the characters are transmitted across the serial line. This function
attempts to insert the characters into the transmission queue, and return values
correspond accordingly.
timeout specifies the amount of time in milliseconds to wait. If timeout is
TIMEOUT_ASAP, the function will return immediately if any of the characters
cannot be queued immediately. If timeout is TIMEOUT_FOREVER, the function
will not return until all the characters are queued successfully.
If all the characters can be queued immediately, MVIsp_Puts returns
MVI_SUCCESS. If the characters cannot be queued immediately, MVIsp_Puts
tries to queue the characters until the timeout elapses. If the timeout elapses
before the characters can be queued, MVI_ERR_TIMEOUT is returned.
If len is not NULL, MVIsp_Puts writes to the int pointed to by len the number of
characters queued successfully. len is written for successfully sent characters as
well as timeouts.
Note: If handshaking is enabled and the receiving serial device has paused transmission, timeouts
may occur after the queue becomes full.
Return Value
MVI_SUCCESS
the characters were sent successfully
MVI_ERR_NOACCESS
comport has not been opened
MVI_ERR_BADPARAM
invalid parameter
MVI_ERR_TIMEOUT
timeout elapsed before characters sent