ProSoft Technology MVI69-ADM User Manual
Page 127

MVI-ADM ♦ 'C' Programmable
Application Development Function Library - ADM API
'C' Programmable Application Development Module
Developer's Guide
ProSoft Technology, Inc.
Page 127 of 342
February 20, 2013
ADM_DAWriteRecvCtl
Syntax
int ADM_DAWriteRecvCtl(ADMHANDLE adm_handle, ADM_INTERFACE *adm_interface_ptr,
int app_port, int marker);
Parameters
adm_handle
Handle returned by previous call to ADM_Open
adm_interface_ptr
Pointer to ADM_INTERFACE structure which contains structure
pointers needed by the function
app_port
Application serial port referenced
marker
Flow control symbol to output to the data analyzer screen
Description
This function may be used to send a receive flow control symbol to the data
analyzer screen. The control symbol will appear between two square brackets:
[R+], [R-], [CS].
adm_handle must be a valid handle returned from ADM_Open.
Valid values for marker are:
RTSOFF
[R-]
RTSON
[R+]
CTSRCV
[CS]
MVI94 Note
Only application port 0 is valid for the MVI94.
Return Value
MVI_SUCCESS
No errors were encountered
MVI_ERR_NOACCESS
adm_handle does not have access
MVI_ERR_BADPARAM
Value of marker is not valid
Example
ADMHANDLE adm_handle;
ADM_INTERFACE *interface_ptr;
ADM_INTERFACE interface;
interface_ptr = &interface;
ADM_DAWriteRecvCtl(adm_handle, interface_ptr, app_port, RTSON);
See Also
ADM_DAWriteSendCtl (page 126)