3. Installation

3.1 Install Industrial Ethernet Extender – IVC-2002

The Industrial Ethernet Extender does not require any software
configuration. Users can immediately use any feature of this product
simply by attached the cables and plug power on. There is some
key limitation on the Industrial Ethernet Extender. Please check the
following items:

IVC-2002: The device is used for Point-to-Point connection only
(Master device to Slave device) and has equipped with one RJ-11 and
one BNC connectors for VDSL2 port for network link connection.

Phone wire: Depending on the quality of telephone line, the maximum
distance of one VDSL segment is 1.4km (4593ft) with AWG 24
telephone wires.

Coaxial: Depending on the quality of coaxial cable, the maximum
distance of one VDSL segment is 2.4km (7874ft) with 5C coaxial cable.

The distances will be changed by the quality of telephone wires and
coaxial cables.