2.1.2 MODE DIP Switch

The Industrial Ethernet Extender provides 4 selective transmission
modes. By switching the transmission modes, you can obtain a best
transmission mode to suit with phone line quality or distance of
connectivity. The following is the summary table of transmission setting,
bandwidth and distance extensibility tested for AWG 24 (0.5mm)
twisted-pair without noise and cross talk.

DIP Switch

DIP-1

DIP-2

DIP-3

DIP-4

Function

Mode

Link Type

Band Plan

SNR

OFF

Master

RJ-11

Symm

9dB

ON (default)

Slave

BNC

Asymm

6dB

Master / Salve

l

t Master (Central Office) – the Master device mode, usually the

Master device will be located at the data center of ISP or enter-
prise to link to the backbone.

t Slave (Customer Premises Equipment) – the Slave device mode,

usually the Slave device will be located at branch office, home or
remote side as the long reach data receiver. The Slave also can be
connected to the PC, IP Camera or Wireless Access Point and etc
network devices.

Note

When the Industrial Ethernet Extender operate at Slave
mode, the DIP switch 2,3,4 is no function.

Link Type

l

t BNC mode allows IVC-2002 to connect and data transfer by using

BNC cable

t RJ-11 mode allows IVC-2002 to connect and data transfer by using

Telephone Wire