PLANET WGSD-10020 User Manual
Page 331
User’s Manual of WGSD / WGSW Layer 2+ Series
Interval Time (10~300s)
This column allows user to set how long system should issue a ping request to PD to
detecte whether PD is alive or dead. Interval time range is from 10 seconds to 300
seconds.
Retry Count (1~5)
This column allows user to set how many times system retries ping to PD.
For example, if we set count 2, the system will retry ping to the PD but the PD
doesn’t response. Then the PoE port needs to be reset.
Action
Allows user to set which action it will apply if the PD does not respond. The PoE
Switch offers 3 actions as follows:
PD Reboot:
It means system will reset the PoE port that is connected to the
PD.
Reboot & Alarm:
It means system will reset the PoE port and issue an
alarm message via Syslog, SMTP.
Alarm:
It means system will issue an alarm message via Syslog, SMTP.
Reboot Time (30~180s)
This column allows user to set the PoE device rebooting time, due to there are so
many kinds of PoE devices on the market and they have different rebooting time.
The PD alive-check is not a defining standard, so the PoE device on the market
doesn’t report reboots done information to the PoE Switch. User has to make sure
how long the PD will be finished to boot, and then set the time value to this column.
System is going to check the PD again according to the reboot time. If you cannot
make sure the precise booting time, we suggest you set it longer.
Buttons
: Click to apply changes
: Click it to reset configuration which has not been saved yet.
331