4 port sequential – PLANET WGSD-10020 User Manual
Page 322

User’s Manual of WGSD / WGSW Layer 2+ Series
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is
to provide information about the maximum power required by the PD during operation. However, to improve power management
at the PSE, the PD provides a signature about Class level.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes.
A PD will return to Class 0 to 4 in accordance with the maximum power draw as specified by
Table 4-16-2.
Class
Usage
Range of maximum power used by the PD
Class Description
0
Default
12.95 watts (or to 15.4 watts for AF mode)
25.5 watts (or to 30.8 watts for AT mode)
Mid power or High power
1
Optional
0.44 to 3.84 watts
Very low power
2
Optional
3.84 to 6.49 watts
Low power
3
Optional
6.49 to 12.95 watts (or to 15.4 watts)
Mid power
4
Optional
12.95 to 25.50 watts (or to 30.8 watts)
High power
Table 4-16-2 Device Class
4.16.4 Port Sequential
This page allows the user to configure the PoE Ports started up interval time. The PoE Port will start up one by one as
Figure
4-16-3
shows.
Figure 4-16-3:
PoE Port Sequential Power Up Interval Configuration Screenshot
The PoE port will start up after the whole system program has finished running.
322