Poe temperature, Poe usage – PLANET FGSD-1022 User Manual
Page 205
User’s Manual of FGSD-1022 Series
poe temperature
Description:
Configure System PoE Temperature Threshold information
Command Level
Global Configuration
Syntax:
poe temperature
{ thershold } {0-100}
Parameters:
<0-100> Temperature Threshold: 0~100 C
PoE temperature command has included in FGSD-1022HP only.
Example:
Switch(config)# poe temperature threshold 60
Switch (config)# show poe
Maximum Available Power
System Operation Status
POE Admin mode
Temperature Unit1
Temperature Unit2
Over Temperature
PoE Power Consumption
Temperature Threshold
Usage
Usage Threshold
PoE Power limit mode
:150Watts
: on
: Disable
: 38C/100F
: 35C/95F
: 55 watts
: 30%
: 60
: 0%
: 100%
: Consumption
poe usage
Description:
Configure System PoE Usage Threshold information
Command Level
Global Configuration
Syntax:
poe usage
{ thershold } {0-100}
205