beautypg.com

PLANET FGSD-1022 User Manual

Page 140

background image

User’s Manual of FGSD-1022 Series

140

The page includes the following fields:

Object

Description

PoE PSU Status

PoE PSU Status shows status of power supply for PoE output.

PoE Temperature Unit 1

Display the current operating temperature of PoE chip unit 1.

The unit 1 is in charge of PoE Port-1~Port-4

PoE Temperature Unit 2

Display the current operating temperature of PoE chip unit 2.

The unit 1 is in charge of PoE Port-5~Port-8

Temperature Threshold

Allows user to set temperature threshold manually. System will issue alert
message to system log and syslog if PoE unit temperature over the threshold.

Over Temperature Protection

Enable / Disable over temperature protection.

When the PoE temperature unit 1 / unit2 over 70 degree C then PoE power
budget will be changed by 3 segments as following:

Over 70 Degree C power budget 180 Watts

Over 73 Degree C power budget 170 Watts

Over 76 Degree C power budget 160 Watts

Power limit mode

Allow to configure power limit mode of Web Smart Device. It can choose :

Total Limit mode : Customize power to PoE port

Classification mode : Reserve power to PD by PoE class level

Consumption mode : Deliver power to PD by real power consumption

PoE Usage Threshold

Allows user to set the threshold value for issues alert message if PoE power
usage over the vaule.

Power Allocation

Show currently total PoE power budget.

PoE Function

Can enable or disable the PoE function.

PoE Schedule

Allows user to set PoE schedule profile to offer PoE power according to time
table.

Priority

Set port priority for the POE power management
It can choose the “port priority”, value is :

Critical

High

Low

High priority is “Critical”.

Device class

Class 0 is the default for PDs. However, to improve power management at the
PSE, the PD may opt to provide a signature for Class 1 to 3.

The PD is classified based on power. The classification of the PD is the
maximum power that the PD will draw across all input voltages and operational
modes. A PD shall return Class 0 to 3 in accordance with the maximum power
draw as specified by Table 4-13-1.

Current(mA)

It shows the PoE device current Amp.

This manual is related to the following products: