Avago Technologies

Description

The HCPL-3700/60 Threshold-

Sensing Optocoupler can be used

for sensing the ac/dc power on/off

condition. At the optocoupler input,

only a pair of series resistors R

X

/2 are

required to limit the current. The ac

signal can be filtered with a capaci-

tor at either the input or the output

of the optocoupler. For more infor-

mation refer to Avago Applica tion

Note AN 1004, “Threshold Sensing

for Industrial Control Systems.” The

value of R

X

determines the threshold

sensing voltage.

Performance of Circuit

• HCPL­3760 optocoupler threshold

input current: 1.3 mA (typical)

• Typical optocoupler propaga tion

delay: 10 µs

• Optocoupler common mode tran-

sient immunity: 600 V/µs (typical)

• Maximum input voltage: up to

1000 Vdc, or 800 Vac

Benefits

• HCPL 3700/60’s built­in diode

bridge and hysteresis circuit re-

duces component count

• HCPL­3760’s low threshold sens-

ing current reduces power dissi-

pation

• Threshold voltage can be adjust-

ed by external resistor R

X

References

1) Avago Application Note AN 1004,

“Threshold Sensing for Industrial

Control Systems”

2) HCPL-3700/60 Threshold Sensing

Optocoupler Technical Data

Alternative Avago Parts

HCPL-576X: Hermetically Sealed

Threshold Sensing Optocoupler

AC/DC Voltage Threshold Sensing

Industrial Applications

VOUT

HCPL-3700/60

RL

RX/2

VCC

1

2

3

4

8

7

6

5

RX/2

UP TO

800 Vac

AC INPUT CONFIGURATION

VOUT

HCPL-3700/60

RL

RX/2

VCC

AC

DC+

DC-

AC

VCC

VO

GND

UP TO

1000 Vdc

DC INPUT CONFIGURATION

RX/2

5

ICC

GND

6

VO

8

VCC

3

2
1

4

DC+ INPUT

AC

INPUT

DC– INPUT

IO

HCPL-3700/60 SCHEMATIC

D1

D2

D3

D4

1

2

3

4

8

7

6

5

AC

DC+

DC-

AC

VCC

VO

GND

This manual is related to the following products: