2

Avago Technologies

Category 1 Optocouplers

Category 2 Optocouplers:

Category 3 Optocouplers:

Figure 3. Recommended Safe Operating Area for Input-Output

Voltage-Endurance Voltage for Category 3 Optocouplers.

Figure 4. Optocoupler’s Insulation Parameters.

Figure 1. Recommended Safe Operating Area for Input-Output

Voltage-Endurance Voltage for Category 1 Optocouplers.

Figure 2. Recommended Safe Operating Area for Input-Output

Voltage-Endurance Voltage for Category 2 Optocouplers.

Insulation and Regulation

WARNING: In all cases where regulatory compliance is required, working voltage as defined by the regulatory agency cannot be exceeded.

INPUT-OUTPUT VOLTAGE, Vac

0

0

0

,

0

0

1

1

0

.

0

5,500

0

CUMULATIVE EXPOSURE TIME, HOURS

0

0

0

,

1

1

.

0

4,500

4,000

3,500

3,000

2,000

1,500

1,000

500

2,500

1

10

100

10,000

6N135/6/7/8/9, OPTION 020

HCPL-2502/30/31, OPTION 020

HCPL-2601/02/11/12/30/31, OPTION 020

HCPL-2730/1, OPTION 020

HCPL-3000/3100/3101

HCPL-4502/03/34/62, OPTION 020

HCPL-4661, OPTION 020

5,000

WEAR-OUT REGION

SAFE

OPERATING

REGION FOR

TRANSIENT

INPUT-OUTPUT

VOLTAGE

SAFE OPERATING REGION FOR CONTINUOUS

INPUT-OUTPUT VOLTAGE

ENDURANCE VOLTAGE – 800 Vac

(NOTE: FOR DC OPERATION,

ENDURANCE VOLTAGE IS 1000 Vdc)

LED

DETECTOR

DISTANCE

THROUGH

INSULATION

EXTERNAL

CREEPAGE

EXTERNAL

CLEARANCE

OPTOCOUPLER'S INSULATION PARAMETERS

INPUT-OUTPUT VOLTAGE, Vac

0

0

0

,

0

0

1

1

0

.

0

5,000

0

CUMULATIVE EXPOSURE TIME, HOURS

0

0

0

,

1

1

.

0

4,500

4,000

3,500

3,000

2,000

1,500

1,000

500

2,500

1

10

100

10,000

4N45/6

6N135/6/7/8/9

HCPL-0201/11

HCPL-0452/3

HCPL-0500/1

HCPL-0600/01/11

HCPL-0700/1

HCPL-2200/01/02/11/

12/19/31/32

HCPL-2300

HCPL-2400/11/30

HCPL-2502/30/31

HCPL-2601/02/11/12/

30/31

HCPL-2730/1

HCPL-3700/60

HCPL-4100/4200

HCPL-4502/03/34/62

HCPL-4661

WEAR-OUT REGION

SAFE OPERATING REGION FOR CONTINUOUS

INPUT-OUTPUT VOLTAGE

ENDURANCE VOLTAGE – 800 Vac

(NOTE: FOR DC OPERATION,

ENDURANCE VOLTAGE IS 1000 Vdc)

SAFE

OPERATING

REGION FOR

TRANSIENT

INPUT-OUTPUT

VOLTAGE

INPUT-OUTPUT VOLTAGE, Vac

0

0

0

,

0

0

1

1

0

.

0

5,000

0

CUMULATIVE EXPOSURE TIME, HOURS

0

0

0

,

1

1

.

0

4,500

4,000

3,500

3,000

2,000

1,500

1,000

500

2,500

1

10

100

10,000

HCPL-314J/315J

HCPL-316J

HCPL-7601/11

HCPL-7710

HCPL-7720/1

WEAR-OUT REGION

SAFE OPERATING REGION FOR CONTINUOUS

INPUT-OUTPUT VOLTAGE

SAFE

OPERATING

REGION FOR

TRANSIENT

INPUT-OUTPUT

VOLTAGE

ENDURANCE VOLTAGE – 800 Vac

(NOTE: FOR DC OPERATION,

ENDURANCE VOLTAGE IS 1000 Vdc

HCPL-7800/A

HCPL-7840

HCPL-788J

HSSR-8060/8400