beautypg.com

Avago Technologies ACPL-224-500E User Manual

Page 16

background image

AV02-4387EN

14

Avago Technologies

250

200

100

180

°C

2.5

°C±0.5°C/sec.

3

°C+1°C/-0.5°C

Peak Temperature

245

°C

Peak Temperature

240

°C

Peak Temperature

230

°C

Soldering Time

200

°C

200

°C

30 sec

Pre Heating Rate: 3

°C+1°C/-0.5°C/sec.

Reflow Heating Rate: 2.5

°C±0.5°C/sec.

150

°C

140

°C

Room

Temperature

0

0

50

100

150

200

250

TEMPERATURE (

°C)

TIME (seconds)

30 sec

50 sec

TIGHT

TYPICAL

LOOSE

Pre Heating Time

150

°C, 90±30 sec.

GND BUS

V BUS

CC

OUTPUT

10 mm MAX

0.1µF

HCPL-2601/11

HCPL-2601/11

V

CC

1

2

3

4

8

7

6

5

V

E

V

OUT

GND

ANODE

CATHODE

Avago optocouplers are suitable

for automatic printed circuit board

(PCB) assembly operations including

surface mount assembly. The follow-

ing guidelines are recommended for

proper opera tion and long term reli-

ability of Avago optocouplers.
Solder Reflow Process: Only one sol-

dering operation is recom mended

within the thermal profile shown

in Figure 16. With infrared lamp

heating, use precautions to avoid

localized temperature rise in the

resin. Also, the resin should not be

immersed in the solder. To prevent

chloride corrosion of the lead frame,

halide fluxes should not be used.
Wave Soldering: The maximum

solder temperature allowed is 260°C

for 10 seconds, with the solder 1.6

mm below the seating plane.

electrical disturbances. It is therefore

necessary to have proper shield-

ing and bypassing of the V

CC

and

Ground traces. Bypassing closely

to each of the optocouplers V

CC

-to-

Ground pins with low-inductance

ceramic capacitor is recommended

as shown in Figure 17.
Figure 17 shows an optional PCB

layout for a high speed digital op-

tocoupler for improving electrical

noise immunity. The optional V

CC

and Ground traces between the pin

rows of the optocoupler help shield

the output circuitry from electrical

disturbances on the input pins, thus

improving common-mode rejection.

Solvent Cleaning: The solvent tem-

perature and immersion time should

not exceed 45°C and three minutes

respectively. For ultra sonic cleaning,

environmentally safe solvents such

as ethyl and methyl alcohol are rec-

ommended.
ESD Precautions: Standard electro-

static discharge precau tions should

be taken in handling and assem-

bly of the optocouplers to prevent

damage or degradation of the

device.
Printed Circuit Board Layout: An op-

tocoupler performs reliably only in

a correctly designed circuit. In most

digital optocoup lers the amplifier

at the output is required to operate

with the very low photocurrent from

the photodetector. Consequently

these ampli fiers can be sensitive to

Figure 16. Temperature/Time Thermal Profile.

Figure 17. Optional Printed Circuit Board Layout for Improved Electrical Noise Immunity.

Guidelines for Printed Circuit Board Assembly and Layout