Common Terms

External Clearance

The shortest distance through air,

between conductive input and

output leads, measured in mm.

Refer to Figure 4.

Comparative Tracking Index (CTI)

Outer molding material charac-

terization in the presence of aque-

ous contaminants. The higher the

CTI value, the more resistant the

material is to electrical arc track-

ing. CTI is often used with creep-

age by safety agencies to deter-

mine working voltage.

External Creepage

The shortest distance along the

outside surface, between input

and output leads, measured in

mm. Refer to Figure 4.

Dielectric Insulation Voltage Withstand

Rating

The ability to withstand without

breakdown a 60 second appli-

cation of a defined dielectric insu-

lation voltage between input and

output leads.

Distance Through Insulation

Distance between the photo-

emitter and photodetector inside

optocoupler cavity (also called in-

ternal clearance). Refer to Figure 4.

Installation Class

I Equipment in closed systems

(e.g., telecom) protected

against over voltage with de-

vices such as diverters, filters,

capacitors, etc.

II Energy consuming equip ment

(e.g., appliances) supplied

through a fixed installation.

III Primarily equipment in fixed

installations (e.g., fixed indus-

trial equipment).

IV Primary supply level for indus-

trial factories.

Insulation

Operational - required for correct

equipment operation but not as a

protection against electric shock.

Basic - protects against electric

shock.

Supplementary - independently

applied to basic insulation to pro-

tect against shock in the event of

its failure.

Double - composed of both basic

and supplementary. Reinforced

- A single insulation system com-

posed of several layers (e.g., single

and supplementary).
Internal Clearance

See Distance Through Insulation.
Internal Creepage

The shortest border distance be-

tween two separate insulating ma-

terials measured between emitter

and detector.
Material Group (see Compara tive

Tracking Index)

I 600 < CTI

II 400 < CTI < 600

IIIa 175 < CTI < 400

IIIb 100 < CTI < 175

Partial Discharge

Electric discharge that partially

bridges the insulation between two

electrodes. Avago supports partial

discharge measurements per IEC/

EN/DIN EN 60747-5-2, a technique

developed to evaluate the integ-

rity of insulating materials. IEC/

EN/DIN EN 60747-5-2 philosophy

is that partial discharge testing

offers advantages over Dielec tric

Withstand Voltage testing, which

might adversely affect the insu-

lating material, and over through

insulation distance requirements

which not only increase manufac-

turing costs but also do not neces-

sarily result in acceptable insulat-

ing capability.

Pollution Degree

1 - Nonconductive pollution only.

2 - Only occasional, temporary

conductivity due to condensa-

tion.

3 - Frequent conductive pollu tion

due to condensation.

4 - Persistent conductive pollu tion

due to dust, rain or snow.

Rated Mains Voltage

Primary power voltage declared

by manufacturer. Used to catego-

rize optocoupler maximum allow-

able working voltage.