Syncro CS 9361-8i and Syncro CS 9380-8e Controllers User Guide
November 2014
Chapter 2: Hardware and Software Setup
Syncro CS 9361-8i Cluster-in-a-Box Hardware Setup
7.
Follow these steps to connect the CVFM04 module on your Syncro CS controller by cable to the remote CVPM02
module.
NOTE
The CVFM04 modules come pre-installed on the Syncro CS 9361-8i
controllers.
a.
Place the controller on a flat, clean, static-free surface.
b.
Ground yourself, and make sure that the system is grounded.
c.
Remove the cable that is included in the box.
The cable has a 9-pin connector on one end and a 6-pin connector on the other.
d.
Insert the 9-pin connector on the cable into the 9-pin J1 connector on the CVFM04 module, as shown in the
following figure.
e.
Insert the 6-pin connector into the 6-pin connector on the cable from the remote CVPM02 module.
Align the cable connectors to make sure that they are connected correctly.
Figure
5 Connecting the CVFM04 Module by Cable to the Remote CVPM02 Module
3_01657-04
J1
CacheVault
Flash Module 04
(CVFM04)
CacheVault
Power Module 02
(CVPM02)
Remote Mount
Board