2.5
CURRENT MONITORING (-1URC AND -1URY MODELS ONLY)
Monitored Output Current (Amps) = Voltage drop across Rs (Volts) x Rs (Ohms), where voltage
drop across Rs (see Table 2-3) is measured across ± IMON pins (requires millivoltmeter, range
0 to 200mV). Accuracy of voltage drop across Rs (representing monitored output current) is
±10%; contact Kepco if greater accuracy is required. See Figure 2-16 for typical configuration.
I/O connector pins designated for use for current monitoring are as follows:
I/O Connector
+IMON
–IMON
Slot 1
PS1, PS2
Pin 15
Pin 3
Slot 2
PS1, PS2
Pin 13
Pin 2
Slot 3
PS3, PS4
Pin 15
Pin 3
Slot 4
PS3, PS4
Pin 13
Pin 2
CAUTION:
There is no isolation between ±IMON, alarm circuit and d-c output. +IMON is
also the –V output of the HSF power supply. For -1URY models, +IMON may
also be used for –RC.
FIGURE 2-16. USING CURRENT MONITORING (TYPICAL), -1URC AND -1URY MODELS ONLY
TABLE 2-3. SENSE RESISTOR VALUES
SERIES
3.3V Model
5V Model
12V Model
15V Model
24V Model
28V Model
48V Model
HSF -1UR 50W
0.01 Ohm
0.01 Ohm
0.02 Ohm
0.03 Ohm
0.05 Ohm
0.05 Ohm
0.1 Ohm
HSF -1UR 100W
5 mOhm
5 mOhm
10 mOhm
20 mOhm
20 mOhm
30 mOhm
50 mOhm
HSF -1UR 150W
2.5 mOhm
2.5 mOhm
10 mOhm
10 mOhm
20 mOhm
20 mOhm
30 mOhm